Instrumentation & Control

Monitoring Systems

Monitoring systems measure, display and record what the rig and the well are doing. The group covers hookload and torque instrumentation, standpipe and choke pressure and return flow sensors, pit volume and trip tank systems, chart and electronic drilling recorders, and the alarm and emergency shutdown systems that act on those signals. Each used sensor needs calibrating before service, whatever its last certificate says.

Scope of the group

Sub-CategoryMeasures or doesMain use on the rig
Drilling instrumentationHookload, weight on bit, torque, RPM, block positionSteering the drilling process
Pressure and flow monitoringStandpipe, casing and choke pressure, flow outHydraulics, washouts, kick detection
Tank and volume monitoringPit levels, total active volume, trip tank volumeGains, losses and hole fill on trips
Parameter recordersTime-stamped record of the aboveWell record, incident review, remote monitoring
Alarm and shutdown systemsAlarms and automatic tripsEmergency shutdown, fire and gas, process shutdown

How the sub-Categories differ

The first three measure. Recorders keep the evidence, and alarm and shutdown systems act on it. That split also decides how strict the paperwork is. A pit level sensor feeding a display needs calibration and an Ex certificate. The same sensor feeding a shutdown function inherits the safety integrity requirements of that function, including proof testing and version control.

Pit volume and return flow are the primary surface signs of a kick, so tank and flow sensors carry well control weight beyond their price. Weight and torque readings protect the drill string and the hoisting system. Treat sensors in all three measurement groups as well control or structural equipment, not consumables.

Standards across the group

Integration questions across the group

Records that make used instruments credible

As-found readings matter most. A sensor that was far out of tolerance when removed may have been overloaded, and that can reveal a hidden fault even after a clean recalibration.

Sourcing used monitoring equipment

Instruments drift, and transport knocks shift zero and span. Ask for the last calibration certificate as a record of condition, then plan to recalibrate on your rig. Unused surplus sensors avoid diaphragm and seal wear, but elastomers and fill fluids still age in storage, so check manufacture dates. Matched sets from one supplier save integration work on a reactivation. Naventr passes on the certificates the Seller holds so you can review them before asking for an inspection.

FAQ

Frequently asked questions

Do used drilling sensors need recalibration?

Yes, every used sensor needs calibration against a traceable reference before it goes into service. Drift, transport shocks and aged seals all shift readings, and well control and hoisting decisions depend on them. Keep the Seller's last certificate as a record of condition only.

What is the difference between a drilling recorder and a pit volume totalizer?

A drilling recorder logs parameters against time, while a pit volume totalizer measures and alarms on mud volume. The totalizer adds the active pit levels into one volume and alarms on gains or losses. A recorder may store that volume as one of its channels.

Can I mix sensors from different instrumentation suppliers?

Often you can, if signal type, range, connector and Ex protection match. Many sensors give a 4 to 20 mA output that any display can scale. Hydraulic weight systems and proprietary digital sensors are less interchangeable, so check with the system supplier.

What hazardous-area certification do rig instruments need?

Instruments in classified areas need ATEX or IECEx certification for their zone, gas group and temperature class. Intrinsically safe devices also need a matching barrier and loop documentation under IEC 60079-14. Compare every marking with the rig's hazardous area drawing.

Does a sensor in a shutdown function need anything extra?

Yes, it inherits the requirements of the safety function it serves. Under IEC 61511 that means a device with suitable reliability data or proven-in-use history, defined proof testing, and change control over the replacement model and version.