Water and sanitation equipment treats and distributes fresh water to the people on board an offshore unit and collects their toilet waste. This Category covers potable water treatment, hot water calorifiers, vacuum and gravity toilet systems, and prefabricated sanitary units. Water makers and sewage treatment plants have their own Categories.

How the water and sanitation chain works

Fresh water from the water maker or a supply boat goes into potable water tanks. A treatment train then disinfects it with chlorine dosing or UV, and remineralises desalinated water so it stops attacking pipework. The treated water feeds the cold circuit and the calorifiers, which heat and store hot water for cabins, galley and laundry. Toilet waste travels through vacuum or gravity piping to the sewage treatment plant. Grey water from showers and basins usually drains by gravity on a separate line.

Configurations

Key specifications

ParameterWhy it mattersTypical classes or units
Toilets served per vacuum generatorDecides whether one generator covers your layoutNumber of toilets, collection tank litres
Flush waterDrives fresh water demand and treatment plant loadLitres (US gal) per flush
Calorifier volume and heat inputMust meet peak shower demand at 60 °C storageLitres (US gal), kW
Calorifier design pressureMust exceed the potable water system pressurebar (psi)
UV or chlorine doseMust disinfect at full system flowm3/h (gpm), mJ/cm2 or mg/l
SupplyPumps and heaters must match the switchboard440 V 60 Hz or 400 V 50 Hz

Standards and what they require

Failure modes and inspection

Documentation

Ask for the system manual, the vacuum generator's running hours and service record, valve and membrane replacement history, calorifier drawings, pressure vessel certificate and safety valve certificates, materials approvals for drinking water parts, and disinfection records.

Integration with your unit

Vacuum piping can run uphill for short lifts, which frees cabin layouts, but the generator must be sized for the total pipe volume and the number of toilets. Gravity toilets cannot connect to a vacuum line, because a gravity bowl has no discharge valve to hold vacuum. Check that the toilet system's discharge suits your treatment plant's inlet. Match calorifier heat input to the available electrical load or steam supply.

Refurbishment and recertification

Vacuum toilet systems refurbish well, because the makers sell standard kits of valves, membranes and pump parts. A used calorifier needs an internal inspection, a hydrostatic test and recertified safety valves before service. Anything that has held drinking water needs flushing, cleaning and disinfection before reuse, which is why unused surplus is the safer buy for potable water parts.

Water production is under water makers and purification, and treatment of collected black water is under sewage treatment plants.

FAQ

Frequently asked questions

How much water does a vacuum toilet use?

A marine vacuum toilet uses about 1 to 1.5 litres a flush, and Evac rates its toilets at about 1.2 litres. A gravity toilet uses several times more. On an offshore unit the saving reduces water maker output and the hydraulic load on the sewage treatment plant.

Can I connect gravity toilets to a vacuum toilet system?

No. A vacuum system needs vacuum toilets, each with a discharge valve and control that open briefly to the vacuum line. A gravity bowl has no valve to hold vacuum, and gravity pipework needs continuous fall that a vacuum layout does not provide.

What should I check on a used vacuum toilet system?

Check that the vacuum generator reaches and holds its working vacuum, and record its running hours. Then inspect the discharge valve membranes, look for urine scale in valves and pipework, check the collection tank for corrosion and confirm the maker still sells wear part kits for the model.

Is used potable water equipment safe to reinstall offshore?

It can be, after flushing, cleaning and disinfection, and once every wetted part is confirmed suitable for drinking water. Calorifiers also need an internal inspection, a hydrostatic test and certified safety valves. Unused surplus avoids most of that work.

What hot water temperature controls Legionella offshore?

The WHO Guide to Ship Sanitation calls for hot water stored at 60 °C (140 °F) or above and returning at 50 °C (122 °F) or above. Cold water should stay below 25 °C (77 °F). Check that a used calorifier's heater and thermostat can hold those temperatures at your peak demand.