Electrical Systems

Electrical Systems covers the equipment between a rig's generators and its motors. The group includes variable frequency drives for drilling machinery and thrusters, main and emergency switchboards with their transformers and distribution, and the power management and generator control systems that run the plant. Used and surplus Electrical Systems equipment is mostly spares for a lineup you already run, or a complete package for an SCR to AC conversion or a reactivation.

How power moves through a rig

Generators connect to the main switchboard, which on a dynamically positioned (DP) unit is split into two or more sections by bus-tie breakers. Drilling and thruster drives take power from the board, usually through phase-shifting transformers, and convert it to variable-frequency AC for each motor. Step-down transformers feed motor control centres, lighting and accommodation at 440 V, 230 V or 120 V. The power management system watches generator load and drive demand and limits drive power before the plant overloads.

Choosing between the sub-Categories

Sub-CategoryWhat it coversMain risk when used
Variable frequency drives (VFD)Drilling and thruster drive lineups, inverter modules, brakingStored capacitors, firmware match
Switchboards and power distributionMV and LV switchgear, breakers, transformers, MCCsBreaker wear, fault rating match
Electrical control systemsPower management, generator controllers, PLCsSoftware, licences, OEM support

Go to Variable frequency drives (VFD) for drive lineups and spare modules. Switchboards and power distribution covers the boards, breakers and transformers. Electrical control systems covers the hardware and software that decide which generators run.

A spare that matches what you already run is mainly a part-number and firmware question. A conversion or a new lineup is an engineering project. It needs a load flow, short-circuit, harmonic and protection study, new cabling and cooling, control integration, and class approval of the modified installation.

Standards across the group

Integration questions that cut across the group

What matters most when sourcing used

Electrical equipment degrades in storage as well as in service. Capacitors lose condition without voltage, insulation absorbs moisture and contacts corrode. Ask for storage conditions, the date the equipment was last energised and any test reports from then. Obsolescence is the second risk, so check the OEM's lifecycle status for each product family before you commit.

Ask for these records with any used electrical equipment:

Plan for the work after delivery too. Drives may need capacitor reforming, switchgear needs breaker and relay tests, and control hardware needs a bench test with your application loaded. Class surveys the installation once it is connected. Naventr lists part numbers, firmware versions and documents as the Seller provides them, so your engineers can check the match.

FAQ

Frequently asked questions

Can I convert an SCR rig to AC drives with a used drive lineup?

Yes, a complete used or unused surplus AC lineup can be the basis of an SCR to AC conversion. The drives are only part of the work. You also need AC motors, new transformers or rectifiers, cabling, cooling, control integration, a harmonic and protection study, and class approval of the modified installation.

Which standard governs electrical installations on a drilling unit?

IEC 61892 governs electrical installations on mobile and fixed offshore units up to 35 kV, with part 5 for mobile units and part 7 for hazardous areas. Class rules, the MODU Code and IEC 60092 equipment standards apply alongside it.

Does changing a drive or switchboard affect my DP notation?

Yes, it can, because the power plant is part of the DP redundancy design. A change to switchboards, bus-ties, drives or power management needs an updated FMEA and proving trials before class confirms the notation.

What harmonic distortion limit applies on a rig switchboard?

IACS UR E24 sets a default limit of 8% total harmonic voltage distortion on the main busbars, unless the design shows that higher levels are safe for the connected equipment. Adding diode-fed drives can push a board past that limit.